Building transformers carry power to HVAC, elevators, IT and lighting. SV500 records load ratio and harmonic trends from secondary-side voltage and current to screen for signs of transformer stress.

Target equipment
Distribution unitsSecondary feedersTap-changer units
Key challenges

Operating challenges

Transformer degradation can lead to a building-wide outage.

01

Degradation and outage risk

Aging of the transformer that powers the whole building raises the risk of a blackout.

02

Harmonics and rising load

Non-linear loads and added equipment can stress transformers, so long-term trends matter.

How SV500 diagnoses

What SV500 detects

SV500 analyzes secondary-side voltage and current of the transformer.

01

Winding-related signs

Tracks secondary imbalance, harmonics and load ratio trends. Confirmation uses insulation resistance and dissolved gas tests.

02

Harmonics (THD), load ratio

Records voltage/current THD with load ratio and matches high-harmonic periods to running loads to narrow the source circuit.

03

Leakage current

Trends leakage only on circuits fitted with a ZCT. Insulation condition is confirmed by periodic insulation tests.

04

Adaptive thresholds

Machine learning learns each asset's normal condition and judges its status with load-dependent adaptive thresholds, rather than fixed limits.

05

Web dashboard and integration

Check diagnostic status in real time on the device's built-in web dashboard without a site visit, and connect to higher-level systems such as BMS or SCADA over Modbus TCP/RTU. Additional interfaces such as MQTT depend on the project configuration.

Expected benefits

Benefits

Decide when to inspect transformers from data and reduce outage risk.

01

Inspection/renewal timing

Read load ratio and harmonic trends alongside maintenance history.

02

Lower outage risk

Event records before protection trips let you check recurring periods first.

03

Maintenance priorities

Compare health grades across equipment on one common basis.

Operational Impact of edgeSV

Continuous monitoring and early detection support availability, maintenance and energy efficiency.

20~40% Reduction in unplanned downtime
10~25% Maintenance cost savings
5~15% Energy savings
10~20% Longer equipment life

Illustrative ranges, not verified SV500 results. Actual outcomes depend on site conditions and corrective actions; PoC validation is required.