edgeSV is the equipment health brand of NTEK System Co., Ltd. ntek@nteksys.com
edgeSV
Request a demo
Large power transformer installed at an industrial electrical facility
Home / Product / SV500 Transformer
SV500 · Transformer condition monitoring

Analyze transformer health through electrical signalsEdge AI predictive maintenance for transformers

Monitor transformer operating condition in one device—from winding, core, bushing, and tap-changer indicators to power quality and energy.

Overview

One platform for transformer diagnostics and power management

SV500 uses Edge AI to analyze three-phase voltage and current patterns and monitor electrical and mechanical indicators of transformer abnormalities. It works with existing PT and CT signals, and its two independent channels can monitor the primary and secondary sides or two separate circuits.

2 channels Independent measurement
Edge AI Machine-learning analysis
8 kSps Waveform-based analysis
CBM Condition-based maintenance
SV500

Key features

01 Edge AI Analytics

Transformer-specific diagnostics

Time- and frequency-domain characteristics of voltage and current are analyzed for early warning signs.

  • 32 kSps measurement / 8 kSps waveform-based analysis
  • Spectrum analysis including FFT and PSD
  • Machine-learning baseline and anomaly detection
02 Transformer Monitoring

Transformer condition monitoring

Changes in electrical signal patterns indicate potential issues in major components.

  • Windings and core: displacement, insulation degradation, and saturation
  • Bushings and tap changers: ground faults, voltage events, and switching transients
  • Load: reactive power, power factor, and unbalance
03 Power Quality & Energy

Power quality and energy

Primary- and secondary-side power conditions are analyzed together.

  • Sag/swell, interruption, and transient detection
  • THD, TDD, harmonics through the 63rd order, and unbalance
  • Power, power factor, energy, and ITIC / EN 50160 evaluation
04 Web Dashboard

Built-in web dashboard

View results and configure the device in a browser without installing dedicated software.

  • Real-time measurements, diagnostic results, and trends
  • Up to 32 alarms plus event history and waveform review
  • Combined asset-condition, power-quality, and energy reports
SV500 DIAGNOSTICS

Key diagnostic functions

Analyze transformer voltage and current patterns alongside power-quality changes to identify early indicators in major components.

01 Transformer components

Windings, core, bushings, and tap changer

  • Winding displacement, insulation degradation, and saturation
  • Ground faults, voltage events, and switching transients
  • Reactive power, power factor, and unbalance changes
02 Power quality

Supply events and load changes

  • Sag, swell, interruption, and transient detection
  • THD, TDD, harmonics through the 63rd order, and unbalance
  • Power, power factor, and energy evaluation
03 Condition analytics

Baseline and trend changes

  • 32 kSps measurement and 8 kSps waveform-based analysis
  • Spectrum analysis including FFT and PSD
  • Machine-learning baseline and anomaly detection
SV500 SYSTEM

System configuration and communications

Review the full SV500 application architecture and LAN and RS-485 connection examples.

SV500

Specifications

SV500 equipment condition monitoring device
Measurement input (voltage) Input type Supports 3-phase 3-wire (3P3W) and 3-phase 4-wire (3P4W)
Voltage channels L1, L2, L3, Ln-1, L4, L5, L6, Ln-2
Voltage range Up to 400 V (L-N) / 690 V (L-L)
Sampling 32 kHz waveform-based measurement
Accuracy Voltage ±0.2%
Measurement input (current) Input type External CT (Current Transformer)
Current channels L1, L2, L3, L4 (leakage), L5, L6, L7, L8 (leakage)
Measurement range Approx. 5 mA to 3,000 A (depending on CT specification)
Supported CT types 5A CT, mV-output CT, Rogowski coil, and more
Accuracy Current ±0.5%
Communication / interface RS485 2 ports (Master 1, Slave 1), Modbus RTU support
Ethernet Built-in 2-port switch, 10/100/1000 Mbps
Protocols Modbus TCP, Modbus RTU
USB-C Console access, firmware updates, Wi-Fi/LoRa module expansion
Power supply Input power DC 24 V
Power consumption Approx. 5 W or less (typical operation)
Protection Internal power protection against overvoltage/overcurrent
BUILT-IN WEB UI

Transformer condition and events in one view

Use a browser to review transformer condition analytics, power quality, alarms and events, and long-term trends.

01

Core monitoring

  • Real-time voltage and current acquisition with high-speed FFT analysis
  • Unified diagnostic data for load behaviour, power quality, and operating changes
02

Reports and analytics

  • Digital-twin and ML/AI-based anomaly detection
  • Condition analysis for key components including windings, bushings, and tap changers
03

Settings and asset management

  • Unified real-time measurements, power quality, and diagnostic results
  • Events, alarms, history, and reporting

Move to condition-based transformer maintenance with SV500