Operating conditions that change with output
Airflow and load vary with generation output and VFD drives are increasing, so fan condition is hard to judge with fixed criteria alone.
Fan motor condition is tracked, such as rising bearing defect indicators ahead of an outage.
Forced draft fans (FDF) supply combustion air to the boiler, induced draft fans (IDF) exhaust the combustion gas, and primary air fans (PAF) send primary air to the coal mills. In this scenario SV500 analyzes the voltage and current signals of the motors and VFDs that drive these fans to detect abnormalities in the fans and motors early.
Draft fans run for long hours under operating conditions that change with generation output.
Airflow and load vary with generation output and VFD drives are increasing, so fan condition is hard to judge with fixed criteria alone.
It is hard to check on site, one by one, the condition of fans installed in several places around the boiler.
SV500 uses ESA to analyze the electrical signals of fan drive motors and VFDs and diagnose abnormalities in the fans and motors.
Detects fan mechanical unbalance, blade and vane damage and flow turbulence.
Detects bearing problems, broken rotor bars, static and dynamic eccentricity, shaft misalignment, soft foot and load-related problems.
For fans driven by a VFD, SV500 analyzes voltage, current and frequency signals on the VFD secondary (output) side at 8 kHz to predict and diagnose potential faults.
Analyzes voltage sag/swell, total harmonic distortion (THD) and voltage and current imbalance in real time to identify equipment impact and abnormal conditions caused by poor power quality at an early stage.
Machine learning learns the normal state of each asset and judges condition with thresholds that adapt to load. Criteria matched to each asset and load condition are applied instead of fixed thresholds.
The equipment web server dashboard shows status per diagnostic parameter in real time, so condition can be checked without a site visit, and data can be integrated with upper-level systems over Modbus RTU, Modbus TCP, MQTT and RESTful API.
Abnormalities in scattered fan equipment can be identified early and remotely so maintenance can be planned.
Detects potential failures early to minimize unexpected incidents and risk.
Diagnostic data helps predict and optimize maintenance schedules.
Higher operating efficiency helps reduce energy consumption, maintenance cost and downtime.
SV500 analyzes the voltage and current signals of the motors and VFDs that drive draft fans with ESA and, with adaptive thresholds that follow operating conditions, detects abnormalities such as mechanical unbalance, bearing problems and blade damage early.
Name the one that matters most and we will set out the diagnostics and measurement points for it.