edgeSV is the equipment health brand of NTEK System Co., Ltd. ntek@nteksys.com
edgeSV
Request a demo
Overview

Feed pumps are key plant auxiliaries that supply water to the boiler. In this scenario SV500 measures and analyzes the three-phase voltage and current signals of the pump drive motors with PTs and CTs in the electrical room to diagnose the condition of the pumps and motors without attaching sensors to the pump itself.

Target equipment
Boiler feed pumpsPump drive motorsVFD
Key challenges

Operating challenges

If a pump in the feedwater system stops, power plant operation is affected immediately.

01

Failures that lead to a plant trip

Cases have been reported in which a feedwater pump stopped during operation, cutting the water supply and tripping the plant. In NETL analysis in the US, 15% of coal-fired forced outage causes were attributed to balance of plant (BOP) equipment.

02

Gaps between inspection intervals

Between periodic inspections there is little means of checking the condition of running pumps and motors.

How SV500 diagnoses

What SV500 detects

SV500 uses ESA to analyze the electrical signals of feed pump drive motors and diagnose pump flow abnormalities and motor and drive faults.

01

Pump flow abnormality detection

Detects cavitation, flow turbulence and blade and vane damage in the pump.

02

Motor and drive diagnosis

Detects mechanical unbalance, bearing problems, broken rotor bars, static and dynamic eccentricity, shaft misalignment, winding insulation degradation and load-related problems.

03

VFD operation diagnosis

For pumps driven by a VFD, SV500 analyzes voltage, current and frequency signals on the VFD secondary (output) side at 8 kHz to predict and diagnose potential faults.

04

Power quality monitoring

Analyzes voltage sag/swell, total harmonic distortion (THD) and voltage and current imbalance in real time to identify equipment impact and abnormal conditions caused by poor power quality at an early stage.

05

Adaptive thresholds

Machine learning learns the normal state of each asset and judges condition with thresholds that adapt to load. Criteria matched to each asset and load condition are applied instead of fixed thresholds.

06

Web dashboard and data integration

The equipment web server dashboard shows status per diagnostic parameter in real time, so condition can be checked without a site visit, and data can be integrated with upper-level systems over Modbus RTU, Modbus TCP, MQTT and RESTful API.

Expected benefits

Benefits

Abnormalities in feedwater system pumps can be identified early so maintenance can be planned.

01

Early detection of potential failures

Detects potential failures early to minimize unexpected incidents and risk.

02

Optimized maintenance schedules

Diagnostic data helps predict and optimize maintenance schedules.

03

Lower cost and downtime

Higher operating efficiency helps reduce energy consumption, maintenance cost and downtime.

SV500 measures the voltage and current signals of feed pump drive motors in the electrical room, analyzes them with ESA and, with adaptive thresholds learned per asset, detects abnormalities in pumps and motors such as cavitation, bearing problems and rotor faults early.

Which asset comes first?

Name the one that matters most and we will set out the diagnostics and measurement points for it.

Request a demo