Risk of failing to start
Long-idle equipment needs start-up, stabilization and load response recorded at every periodic test to know its readiness.
Standby units are evaluated whenever they run, so their condition is known before a failover.
Standby cooling pumps, fans and emergency generators run so little that faults can stay hidden. SV500 uses electrical signature analysis (ESA) to record current and load during test runs, so readiness can be compared before changeover.
Standby equipment can look normal until it is actually started and a problem appears.
Long-idle equipment needs start-up, stabilization and load response recorded at every periodic test to know its readiness.
Without a known baseline, reliability and maintenance planning suffer, so each test run needs to be recorded.
Analyzes the VFD’s voltage output and current waveforms to diagnose faults in rectifier diodes, DC-link capacitors, and switching semiconductors (SCRs or IGBTs). Also analyzes the condition of power supply and power quality of the VFD.
Without installing additional sensors on the equipment, analyzes the voltage and current waveforms supplied to the motor to diagnose mechanical faults (Cavitation, Soft Foot, Bearing, Vibration, etc.), electrical faults (Stator, Cable connection, Heat, Noise, etc.) and Load fluctuation fault.
For power quality diagnosis, saves power quality indicators such as voltage, current, interruptions, sags, harmonics, etc. in trend data.
Performs all diagnostic analysis directly on the edge device. Built-in memory and storage—2GB DDR, 8GB eMMC, and SD card support up to 256GB—enable long-term storage of diagnostic data and waveforms without transmitting them to a server. The built-in web-based UI/UX provides access to real-time data, diagnostic result of the equipment, diagnostic data of the power quality, alarm events, reports and etc. without a separate server.
Test-run records support changeover readiness checks and maintenance ordering of standby units.
Start-up and load trends from test runs feed readiness checks.
Round-by-round records show which standby unit needs work first.
Compares health grades on one basis to allocate maintenance staff.
Continuous monitoring and early detection support availability, maintenance and energy efficiency.
Illustrative ranges, not verified SV500 results. Actual outcomes depend on site conditions and corrective actions; PoC validation is required.
Name the one that matters most and we will set out the diagnostics and measurement points for it.